Effective Intraday 1 Cycle (14:00) for the gas day of October 18, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
BUMPED
· STA 325 (Segment 324 FH) - through 100% of PS IT at a rate of $.16 due to nominations in excess of operational capacity ; 5,163 Dths
RESTRICTIONS
· Tres Pal/TGP Tres Palacios Storage: Delivery Meter (Pin 421055) - through approx 48% of IT increases due to imbalance management quantity exceeded; 7,151 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 37,598 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 99% of SOP increases due to imbalance management quantity exceeded; 147,711 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SOP increases due to operational concerns; 17,520 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 37% of SIPps increases due to nominations in excess of operational capacity; 23,936 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 9,956 Dths
· STA 204 (Segment 204 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 55,193 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 to MLV 310; 55,000 Dths
· MLV 314 East (Segment 314 BH) - through approx 73% of SOP increases due to nominations in excess of operational capacity; 77,754 Dths
· STA 321 (Segment 321 FH) - through approx 63% of SOP increases due to nominations in excess of operational capacity; 160,780 Dths
· STA 325 (Segment 324 FH) - through 100% of IT increases due to nominations in excess of operational capacity; 93 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 17% of SOP increases due to nominations in excess of operational capacity; 9,775 Dths
· STA 224 (Segment 224 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 15,604 Dths
· Z5HC North (Segment 299 FH) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 61,692 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 262,640 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 115,485 Dths
LINEPACK RESTRICTIONS
Payback system wide will continue to be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.