TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  10/17/2022 2:42:41PM Notice End Date/Time:  10/18/2022 9:00:00am
Post Date/Time:  10/17/2022 2:42:41 PM Notice ID: 384657
Reqrd Rsp:  1 Rsp Date:  10/17/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 10-18-2022 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of October 18, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         STA 1 (Segment 101 BH) - through approx 33% of SOP  due to nominations in excess of operational capacity; 28,825 Dths

·         STA 823 (Segment 823 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 30,715 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 69% of SOP  due to imbalance management quantity exceeded; 205,449 Dths

·         STA 834 (Segment 834 BH) - through approx 57% of SOP  due to nominations in excess of operational capacity; 102,753 Dths

·         STA 860 (Segment 860 BH) - through approx 54% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 31,985 Dths

·         TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through approx 99% of SOP  due to nominations in excess of operational capacity; 19,738 Dths

·         Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 9% of SIPps  due to imbalance management quantity exceeded; 6,763 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 30% of SIPps  due to nominations in excess of operational capacity; 117,335 Dths

·         STA 110 South (Segment 187 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 58,381 Dths

·         STA 204 (Segment 204 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 121,193 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP  due to force majeure at MLV 309 to MLV 310; 130,000 Dths

·         MLV 314 East (Segment 314 BH) - through approx 57% of SOP  due to nominations in excess of operational capacity; 100,705 Dths

·         STA 315 (Segment 315 BH) - through approx 67% of SOP  due to nominations in excess of operational capacity; 412,551 Dths

·         STA 321 (Segment 321 FH) - through approx 68% of SOP  due to nominations in excess of operational capacity; 491,184 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 32% of SIPss  due to nominations in excess of operational capacity; 123,639 Dths

·         MLV 336 East (Segment 336 FH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 3,939 Dths

·         STA 224 (Segment 224 FH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 87,296 Dths

·         Z5HC North (Segment 299 FH) - through approx 72% of SOP  due to nominations in excess of operational capacity; 552,980 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 635,192 Dths

·         MLV 273 (Segment 284 FH) - through approx 97% of SOP  due to nominations in excess of operational capacity; 192,248 Dths

LINEPACK RESTRICTIONS

No Payback TO the pipe will be scheduled Systemwide until further notice.  Payback system wide will continue to be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

No Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide until further notice.

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.