Effective Timely Cycle (9:00) for the gas day of October 17, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· STA 823 (Segment 823 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 37,000 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 66% of SOP due to imbalance management; 179,934 Dths
· STA 834 (Segment 834 BH) - through approx 48% of SOP due to nominations in excess of operational capacity; 76,166 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 65,627 Dths
· TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through 100% of SOP due to nominations in excess of operational capacity; 19,846 Dths
· Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 14% of SIPps due to imbalance management; 11,637 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 33% of SIPps due to nominations in excess of operational capacity; 137,583 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 26,137 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to force majeure at ML 309 to MLV 310; 71,000 Dths
· STA 313 West (Segment 307 BH) - through 100% of SOP due to force majeure at MLV 309 to MLV 310; 59,000 Dths
· MLV 314 East (Segment 314 BH) - through approx 96% of SOP due to nominations in excess of operational capacity; 169,746 Dths
· STA 315 (Segment 315 BH) - through approx 70% of SOP due to nominations in excess of operational capacity; 299,249 Dths
· STA 321 (Segment 321 FH) - through approx 50% of SOP due to nominations in excess of operational capacity; 353,288 Dths
· Z5HC North (Segment 299 FH) - through approx 70% of SOP due to nominations in excess of operational capacity; 538,792 Dths
· STA 245 (Segment 245 FH) - through approx 91% of SOP due to nominations in excess of operational capacity; 583,501 Dths
· MLV 273 (Segment 284 FH) - through approx 95% of SOP due to nominations in excess of operational capacity; 213,207 Dths
LINEPACK RESTRICTIONS
No Payback TO the pipe will be scheduled Systemwide until further notice. Payback system wide will continue to be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
No Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide until further notice.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.