Effective Intraday 2 Cycle (18:00) for the gas day of October 12, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· Tres Pal/TGP Tres Palacios Storage: Delivery Meter (Pin 421055) - through approx 25% of SOP increases due to imbalance management; 1,253 Dths
· Etc Tig/TGP Chatham Jackson Receipt Meter (Pin 412830) - through 100% of SOP increases due to nominations in excess of operational capacity; 6,075 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 37,000 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 85% of SOP increases due to imbalance management; 125,521 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 73,517 Dths
· TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through 100% of SOP increases due to nominations in excess of operational capacity; 90 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SOP increases due to operational concerns; 3,793 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 97% of SIPps increases due to nominations in excess of operational capacity; 5,917 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 to MLV 310; 55,000 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 135,514 Dths
· Z5HC North (Segment 299 FH) - through approx 23% of SOP increases due to nominations in excess of operational capacity; 19,224 Dths
· STA 245 (Segment 245 FH) - through approx 84% of SOP increases due to nominations in excess of operational capacity; 121,037 Dths
· MLV 273 (Segment 284 FH) - through approx 87% of SOP increases due to nominations in excess of operational capacity; 32,982 Dths
LINEPACK RESTRICTIONS
No Payback FROM the pipe will be scheduled on the 500 Line until further notice. PALD and PALAO nominations OFF the system will not be scheduled in this area. Payback system wide will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017) (IS-PA, FS-PA). Transfers into TGP Bear Creek from SNG Bear Creek will be allowed only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.