Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  09/01/2022 11:08:01AM Notice End Date/Time:  09/02/2022 9:00:00am
Post Date/Time:  9/1/2022 11:08:01 AM Notice ID: 384124
Reqrd Rsp:  1 Rsp Date:  09/01/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 09-01-2022 ID1
Notice Text:

Effective Intraday 1 Cycle (14:00) for the gas day of September 01, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR SOUTH OF STA 1 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         MLV 406 (Segment 406 BH) - through approx 83% of PIP increases  due to scheduled maintenance and nominations in excess of operational capacity; 1,609 Dths

·         STA 823 (Segment 823 BH) - through 100% of SOP increases  due to operational concerns; 17,179 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 92% of SOP increases  due to imbalance management; 163,706 Dths

·         STA 834 (Segment 834 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 10,317 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 89% of SIPps increases  due to nominations in excess of operational capacity; 26,824 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases  due to force majeure at MLV 309 to MLV 310; 55,000 Dths

·         STA 317 (Segment 317 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 45,850 Dths

·         STA 321 (Segment 321 FH) - through approx 97% of SOP increases  due to nominations in excess of operational capacity; 300,013 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 56% of SOP increases  due to nominations in excess of operational capacity; 28,795 Dths

·         Z5HC North (Segment 299 FH) - through approx 99% of SOP increases  due to nominations in excess of operational capacity; 76,509 Dths

·         STA 245 (Segment 245 FH) - through approx 99% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 189,454 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 160,258 Dths

LINEPACK RESTRICTIONS

No Payback FROM the pipe will be scheduled South of STA 1 in South Texas or South of STA 542 on the 500 until further notice.  PALD and PALAO nominations OFF the system will not be scheduled in these areas.  Additionally, Payback system wide will be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

NONE

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

....