Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  07/31/2022 3:52:34PM Notice End Date/Time:  08/01/2022 9:00:00am
Post Date/Time:  7/31/2022 3:52:34 PM Notice ID: 383765
Reqrd Rsp:  1 Rsp Date:  07/31/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 07-31-2022 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of July 31, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS ON THE 500 LEG BETWEEN STA 860 AND STA 527 FOR LMS-PA, SA ACTING AS BALANCING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM

OFO DAILY CRITICAL DAY 1 FOR SOUTH OF STA 1 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         MLV 406 (Segment 406 BH) - through 100% of PIP increases due to scheduled maintenance and nominations in excess of operational capacity; 2,797 Dths

·         STA 834 (Segment 834 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 91,432 Dths

·         Gulf South/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SOP increases due to operational concerns; 3,000 Dths

·         Transco/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps at the group level (Delivery meters South of STA 542) due to operational concerns; 10 Dths

·         Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SIPps at the group level (Delivery meters South of STA 542) due to operational concerns; 7,391 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPps at the group level (Delivery meters South of STA 542) due to operational concerns; 10,352 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 to MLV 310; 55,000 Dths

·         STA 313 West (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 to MLV 310; 36,414 Dths

·         MLV 314 East (Segment 314 BH) - through approx 83% of SOP increases due to nominations in excess of operational capacity; 20,353 Dths

·         STA 245 (Segment 245 FH) - through approx 89% of SOP increases due to nominations in excess of operational capacity; 115,525 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 38,915 Dths

LINEPACK RESTRICTIONS

No Loans or Park Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services on the 500 Leg between STA 860 and STA 527 until further notice. No Payback FROM the pipe greater than the supply tolerance (100 Dths) will be allowed in on the 500 Leg between STA 860 and STA 527 until further notice.  Payback system wide will be evaluated at each cycle and scheduled only if operationally feasible. 

STORAGE RESTRICTIONS

NONE

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

...