Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  07/26/2022 7:59:01PM Notice End Date/Time:  07/27/2022 9:00:00am
Post Date/Time:  7/26/2022 7:59:01 PM Notice ID: 383718
Reqrd Rsp:  1 Rsp Date:  07/26/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 07-26-2022 ID3
Notice Text:

Effective Intraday 3 Cycle (22:00) for the gas day of July 26, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS ON THE 500 LEG BETWEEN STA 860 AND STA 527 FOR LMS-PA, SA ACTING AS BALANCING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM and OFO DAILY CRITICAL DAY 1 FOR SOUTH OF STA 1 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         Net Mexi/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SA increases  due to operational concerns; 2,911 Dths

·         Entrprse/TGP Agua Dulce Nueces Receipt Meter (Pin 411306) - through 100% of SA increases  due to operational concerns; 1,969 Dths

·         STA 860 (Segment 860 BH) - through approx 23% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 38,536 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  at the group level (Delivery meters South of STA 542)  due to operational concerns; 110 Dths

·         Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SIPps increases  at the group level (Delivery meters South of STA 542)  due to operational concerns; 8,259 Dths

·         TGP/Sng Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPps increases  at the group level (Delivery meters South of STA 542)  due to operational concerns; 4,207 Dths

·         STA 307 (Segment 307 BH) -  through 100% of SOP increases  due to force majeure at MLV 309 to MLV 310; 36,414 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 53,502 Dths

LINEPACK RESTRICTIONS

No Loans or Park Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services on the 500 Leg between STA 860 and STA 527 until further notice. No Payback FROM the pipe greater than the supply tolerance (100 Dths) will be allowed in on the 500 Leg between STA 860 and STA 527 until further notice.  Payback systemwide will be evaluated at each cycle and scheduled only if operationally feasible. 

STORAGE RESTRICTIONS

NONE

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

.