Effective Evening Cycle (9:00) for the gas day of July 18, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES L, 1 AND 2 FOR LMS-PA, SA ACTING AS BALANING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM
OFO DAILY CRITICAL DAY 1 FOR SOUTH OF STA 1 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· MLV 406 (Segment 406 BH) - through 100% of PIP increases due to scheduled maintenance and nominations in excess of operational capacity; 141,506 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 36,938 Dths
· STA 834 (Segment 834 BH) - through approx 33% of SOP increases due to nominations in excess of operational capacity; 58,879 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 101,165 Dths
· Gulf South/TGP Kiln Miss Exchange Hanc Delivery Meter (Pin 420383) - through 100% of SIPps increases due to operational concerns; 7,599 Dths
· Transco/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 110 Dths
· Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SIPps increases due to operational concerns; 5,001 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPps increases due to operational concerns; 5,128 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 17,039 Dths
· STA 204 (Segment 204 BH) - through approx 25% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 18,889 Dths
· Hickory/TGP Mohawk Road Power Plt Delivery Meter (Pin 50789) - through 100% of PAYBACK TGP increases due to nominations in excess of operational capacity; 7,872 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 and MLV 310; 186,610 Dths
· MLV 314 East (Segment 314 BH) - through approx 94% of SOP increases due to nominations in excess of operational capacity; 31,317 Dths
· STA 315 (Segment 315 BH) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 73,922 Dths
· STA 321 (Segment 321 FH) - through approx 78% of SOP increases due to nominations in excess of operational capacity; 155,256 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 90% of SOP increases due to nominations in excess of operational capacity; 187,723 Dths
· Z5HC North (Segment 299 FH) - through approx 85% of SOP increases due to nominations in excess of operational capacity; 124,074 Dths
· STA 245 (Segment 245 FH) - through approx 73% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 150,647 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 182,987 Dths
LINEPACK RESTRICTIONS
No Loans or Park Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services in Zones L, 1 and 2 further notice. No Payback FROM the pipe greater than the supply tolerance (100 Dths) will be allowed in Zones L, 1 and 2 until further notice. Payback system wide will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.