Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  07/13/2022 9:01:24PM Notice End Date/Time:  07/14/2022 9:00:00am
Post Date/Time:  7/13/2022 9:01:24 PM Notice ID: 383575
Reqrd Rsp:  1 Rsp Date:  07/13/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 07-13-2022 ID3
Notice Text:

Effective Intraday 3 Cycle (22:00) for the gas day of July 13, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONE L AND ZONE 1 FOR THE 500 LEG ONLY BETWEEN STA 860 AND STA 534 FOR LMS-PA, SA ACTING AS BALANING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         TGP/Sng Toca Exchange St Bernard Delivery Meter (Pin 420556) - through 100% of SIPps increases  due to operational concerns; 100 Dths

·         Gulfsth/TGP Kiln Miss Exchange Hanc Delivery Meter (Pin 420383) - through 100% of SIPps increases  due to operational concerns; 200 Dths

·         Fgt/TGP Carnes Mississippi Stone Delivery Meter (Pin 420366) - through 100% of SIPps increases  due to operational concerns; 56 Dths

·         Sesh/TGP Petal Interconnect: Rip 53 Delivery Meter (Pin 421059) - through 100% of SIPps increases  due to operational concerns; 545 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 110 Dths

·         Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SIPps increases  due to operational concerns; 186 Dths

·         STA 860 South 500 Line (Segment 548 BH) - through 100% of SIPps increases  due to force majeure at STA 550; 2,679 Dths

·         STA 307 (Segment 307 BH) - through 100% of SIPps increases  due to force majeure at MLV 309 and MLV 310; 34,460 Dths

·         STA 245 (Segment 245 FH) - through approx 87% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 60,706 Dths

LINEPACK RESTRICTIONS

No Loans or Park Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services on the 500 Leg until further notice. No Payback FROM the pipe greater than the supply tolerance (100 Dths) will be allowed on the 500 Leg until further notice.  Payback systemwide will be evaluated at each cycle and scheduled only if operationally feasible. 

STORAGE RESTRICTIONS

NONE

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

.