Effective Intraday 2 Cycle (18:00) for the gas day of July 07, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONE L AND ZONE 1 FOR THE 500 LEG ONLY BETWEEN STA 860 AND STA 534 FOR LMS-PA, SA ACTING AS BALANING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· STA 409 - Donna Lateral (Segment 490 FH) - through approx 43% of IT increases due to scheduled maintenance and nominations in excess of operational capacity; 8,282 Dths
· STA 834 (Segment 834 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 135,748 Dths
· Gulfsth/TGP Kiln Miss Exchange Hanc Delivery Meter (Pin 420383) - through 100% of SOP increases due to operational concerns; 1,000 Dths
· Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SOP increases due to operational concerns; 34,306 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to nominations in excess of operational capacity; 110 Dths
· Leaf/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SOP increases due to operational concerns; 50,717 Dths
· MLV 548 (Segment 542 BH) - through 100% of SA increases due to emergent repair at STA 542, scheduled maintenance and nominations in excess of operational capacity; 5,000 Dths
· Atmos Ky/TGP Simpson Simpson Delivery Meter (Pin 421000) - through 100% of SIPss increases due to nominations in excess of operational capacity; 13 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 104,288 Dths
· STA 315 (Segment 315 BH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 124,111 Dths
· STA 321 (Segment 321 FH) - through approx 95% of SOP increases due to nominations in excess of operational capacity; 173,238 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 71% of SOP increases due to nominations in excess of operational capacity; 87,289 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP increases due to operational concerns; 7,087 Dths
· STA 237 West (Segment 233 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 4,242 Dths
· Z5HC North (Segment 299 FH) - through approx 47% of SOP increases due to nominations in excess of operational capacity; 30,439 Dths
· STA 245 (Segment 245 FH) - through approx 91% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 205,064 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 34,053 Dths
LINEPACK RESTRICTIONS
No Loans or Park Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services on the 500 Leg until further notice. No Payback FROM the pipe greater than the supply tolerance (100 Dths) will be allowed on the 500 Leg until further notice. Payback systemwide will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.