Effective Intraday 1 Cycle (14:00) for the gas day of July 05, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONE L AND ZONE 1 FOR THE 500 LEG ONLY BETWEEN STA 860 AND STA 534 FOR LMS-PA, SA ACTING AS BALANING PARTIES AND LMS-MA FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· MLV 406 (Segment 406 BH) - through 100% of IT increases due to nominations in excess of operational capacity; 6,696 Dths
· STA 823 (Segment 823 BH) - through approx 61% of SOP increases due to nominations in excess of operational capacity; 22,160 Dths
· STA 834 (Segment 834 BH) - through approx 92% of SOP increases due to nominations in excess of operational capacity; 114,294 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10,010 Dths
· TGP/Sng Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 4,664 Dths
· MLV 548 (Segment 542 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 13,093 Dths
· Atmos Ky/TGP Simpson Simpson Delivery Meter (Pin 421000) - through 100% of SIPss increases due to nominations in excess of operational capacity; 52 Dths
· STA 307 (Segment 307 BH) - through approx 76% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 74,133 Dths
· MLV 314 East (Segment 314 BH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 102,966 Dths
· STA 321 (Segment 321 FH) - through approx 93% of SOP increases due to nominations in excess of operational capacity; 192,456 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 77% of SOP increases due to nominations in excess of operational capacity; 40,551 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP increases due to operational concerns; 6,280 Dths
· STA 237 West (Segment 233 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 33,475 Dths
· Z5HC North (Segment 299 FH) - through approx 48% of SOP increases due to nominations in excess of operational capacity; 42,984 Dths
· STA 245 (Segment 245 FH) - through approx 70% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 131,881 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 209,581 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.