Effective Evening Cycle (9:00) for the gas day of December 08, 2019 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 245 AND STA 325 FOR ALL BALANCING PARTIES FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM
OFO DAILY ACTION ALERT ZONE 0 FOR ALL BALANCING PARTIES FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM
MONTHLY CRITICAL DAY 1 OFO FOR ZONE 4 FOR ALL LMSPA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· STA 9 (Segment 109 BH) - through 100% of SIPps increases due to an emergent repair at STA 9 and nominations in excess of operational capacity; 5,915 Dths
· STA 834 (Segment 834 BH) - through 100% of SA increases due to scheduled maintenance and nominations in excess of operational capacity; 31,230 Dths
· Trnsco/TGP Heidelberg Missisippi Delivery Meter (Pin 420291) - through approx 61% of SIPss increases due to nominations in excess of operational capacity; 15,010 Dths
· STA 860 South 500 Line (Segment 548 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 174,037 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 8,672 Dths
· MLV 314 East (Segment 314 BH) - through approx 39% of SOP increases due to nominations in excess of operational capacity; 12,116 Dths
· STA 321 (Segment 321 FH) - through approx 95% of SOP increases due to nominations in excess of operational capacity; 267,772 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 89% of SOP increases due to nominations in excess of operational capacity; 107,553 Dths
· STA 224 (Segment 224 FH) / HC Zn 5 (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 494,818 Dths
· STA 245 (Segment 245 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 350,287 Dths
· Wright Receipt Meter (Pin 412181) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 212,520 Dths
· STA 261 East (Segment 261 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 113,268 Dths
LINEPACK RESTRICTIONS
No Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing PAL-D or PAL-AO services system wide until further notice
No Payback or Lower Services OFF the pipe in Zone 0
No Payback or Lower Services OFF the pipe DS of STA 245 and STA 325
STORAGE RESTRICTIONS
No Interruptible Storage Injection Services (IS-MA) at Northern (460018) or (IS-PA) at Bear Creek (460017)
No transfers from TGP Bear Creek Storage FS-PA to IS-PA
No transfers from TGP Bear Creek Storage to SNG Bear Creek Storage (IS-PA, FS-PA)
Transfers into TGP Bear Creek from SNG Bear Creek will be allowed under the FS-PA Storage Service ONLY with partner approvals
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.