Effective Timely Cycle (9:00) for the gas day of December 16, 2018 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
None
RESTRICTIONS
MLV 406 (Segment 406 BH) - through 100% of SOP due to nominations in excess of operational capacity; 3,740 Dths
Regency Peoples Road Receipt Meter (Pin 412691) – through approx 6% of SA due to nominations in excess operational capacity; 17,300 Dths
STA 224 (Segment 224 FH) / HC Zn 5 (Segment 299 FH) – through approx 95% of SOP due to nominations in excess of operational capacity; 614,143 Dths
STA 245 (Segment 245 FH) – through approx 92% of SOP due to nominations in excess of operational capacity; 487,562 Dths
STA 261 (Segment 261 FH Discharge) - through approx 75 of SOP due to nominations in excess of operational capacity; 131,465 Dths
MLV 273 (Segment 284 FH) – through approx 85% of SOP due to nominations in excess of operational capacity; 208,409 Dths
MLV 314 (Segment 314 BH) – through approx 64% of SOP due to nominations in excess of operational capacity; 153,257 Dths
STA 315 (Segment 315 BH) – through approx 6% of SOP due to nominations in excess of operational capacity; 66,263 Dths
STA 321 (Segment 321 FH) – through approx 30% of SOP due to nominations in excess of operational capacity; 103,553 Dths
STA 325 (Segment 324 FH) – through approx 36% of SOP due to nominations in excess of operational capacity; 73,255 Dths
Mahwah Delivery Meter (Pin 420207) – through approx 69% of SIPss due to nominations in excess of operational capacity; 129,685 Dths
Rivervale Delivery Meter (Pin 420101) – through 100% of SIPss due to nominations in excess of operational capacity; 10,000 Dths
MLV 336 (Segment 336 FH) – through approx 99% of SOP due to nominations in excess of operational capacity; 31,860 Dths
MLV 355 (Segment 355 BH) – through 100% of SOP due to operational concerns; 994 Dths
LINEPACK RESTRICTIONS
No park withdrawals or loans under rate schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide until further notice
STORAGE RESTRICTIONS
No Authorized Overrun Storage Withdrawals (FSMA-AO, FSPA-AO) accepted from Northern (460018), Portland Storage MA (460025), Portland Storage PA (460020) or Bear Creek Storage (460017)
No Interruptible Storage Withdrawals (ISMA, ISPA) accepted from Northern (460018), Portland Storage MA (460025), Portland Storage PA (460020) or Bear Creek Storage (460017)
No transfers from TGP Bear Creek Storage to SNG Bear Creek Storage (IS-PA, FS-PA)
Transfers into TGP Bear Creek from SNG Bear Creek will be allowed with partner approvals
Customers who elected swing on storage (SSO) or storage swing options (SSO) may swing up to their Maximum Daily Withdrawal Quantity (MDWQ) only
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND
ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED
SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.